Title of article :
A simple, rapid and sensitive semimicro method for the measurement of cyanide in blood
Author/Authors :
Vesey، C J نويسنده , , McAllister، H نويسنده , , Langford، R M نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Abstract :
Urinary excretion of uric acid was found to be extremely low in a 58-year-old female patient with alcaptonuria. This was due to interference with the uricase-peroxidase method used, because analysis using high-performance liquid chromatography (HPLC) showed a normal urinary concentration of uric acid. In vitro experiments demonstrated that a high concentration of homogentisic acid in the patientʹs urine inhibited the peroxidase reaction, possibly due to inhibition of the colour development of 3-methyl-N-ethyl-N-((beta)-hydroxyethyl)aniline (MEHA) and 4-aminoantipyrine, via the peroxidase reaction. A homogentisic acid concentration equivalent to that in plasma did not affect the uricase-peroxidase reaction. This result suggests that any assay based on a peroxidase method is affected by a high urinary concentration of homogentisic acid in patients with alcaptonuria.
Keywords :
Conway diffusion dish , cyanmethaemoglobin , sodium nitroprusside , Smoke inhalation
Journal title :
Annals of Clinical Biochemistry
Journal title :
Annals of Clinical Biochemistry