Title of article :
Stress corrosion cracking of X-70 pipeline steels by eletropulsing treatment in near-neutral pH solution
Author/Authors :
BINGYAN FANG، نويسنده , , Jianqiu Wang، نويسنده , , SUHONG XIAO، نويسنده , , EN-HOU HAN، نويسنده , , ZIYONG ZHU، نويسنده , , Kai-Wei Ke، نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 2005
Pages :
8
From page :
6545
To page :
6552
Abstract :
Slow strain rate tests (SSRT) and environmental scanning electron microscopy (ESEM) were utilized to investigate stress corrosion cracking (SCC) behavior of electropulsed POSCO and Bao Steel X-70 pipeline steels specimens in XJ solution purged with 5% CO2 + 95% N2 at the strain rate of 2E-6/s. The results showed that the ultimate tensile strengths (UTS) were raised considerably for the electropulsed specimens. The UTS for electropulsed POSCO X-70 pipeline steel was enhanced much more compared to electropulsed Bao Steel X-70 pipeline steel. In addition, the relationship among UTS, the original grain size and high voltage in electropulsing treatment was revealed. SCC sensitivity increased with the decreasing electrochemical potential, especially at high cathodic potential. C 2005 Springer Science + Business Media, Inc
Journal title :
Journal of Materials Science
Serial Year :
2005
Journal title :
Journal of Materials Science
Record number :
830476
Link To Document :