Abstract
During the manufacture of glass/phenolic
resin prepreg cloth, the feasibility of near infrared
(NIR) spectroscopy as a technique for the quality
control analysis of the resin content, the volatile
content and the resin pre-curing degree has been
verified. The partial least square (PLS) regression was
used to develop the calibration models by utilizing
several different spectral pretreatments. The optimum
models had determination coefficients (R2) of 98.29 for
the resin content, of 99.50 for the volatile content and
of 97.66 for the pre-curing degree, respectively. The
root mean square errors of prediction (RMSEP) for
the resin content, the volatile content and the precuring
degree were 0.376%, 0.169% and 0.105%,
respectively. The results of the paired t-test revealed
that there was no significant difference between the
NIR method and the standard method. In the manufacture
process of the prepreg cloth, the NIR on-line
monitoring results were used to be the instructions for
the quality control