Title of article :
Application of gas-inducing reactor to obtain high oxygen dissolution in aeration process
Author/Authors :
Chen، Jyh-Herng نويسنده , , Hsu، Yung-Chien نويسنده , , Chen، Y. -F. نويسنده , , Lin، Chih-Chu نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
-2918
From page :
2919
To page :
0
Abstract :
The application of gas-inducing reactor to obtain high oxygen dissolution has been investigated at various operation conditions including agitation speed, temperature (20–40°C), pressure (1.0–1.2 atm) and working liquid levels. Correlations regarding onset speed, agitation power consumption, gas holdup and oxygen mass transfer coefficient were established from experimental data. Onset speed can be accurately predicted with modified Froude number. The agitation power consumptions before and after onset speed is a function of Froude number and working liquid level. Gas holdup is an important factor influencing the mass transfer of oxygen after onset speed. In the study of mass transfer of oxygen (T=20°C, P=1 atm), the highest dissolved oxygen concentration is as high as 39.34–39.92 mg L^-1. The value of kLa is within 0.511–1.792 min^-1. The kLa is not affected by the oxygen gas pressure (1.0–1.2 atm). However, kLa increases with increasing temperature. The gas-inducing reactor of this study has higher kLa than the other type of gas-inducing reactor under the same unit volume power consumption. The pure oxygen utilization rate of this system can be as high as 100%.
Keywords :
Oxygen utilization rate , mass transfer , Onset , Gas-inducing reactor
Journal title :
Water Research
Serial Year :
2003
Journal title :
Water Research
Record number :
84658
Link To Document :
بازگشت