Title of article :
Modeling and experimental validation of internal faults in salient pole synchronous machines including space harmonics Original Research Article
Author/Authors :
X. Tu، نويسنده , , L.-A. Dessaint، نويسنده , , M. El Kahel، نويسنده , , A. Barry، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Considering the space harmonics caused by the faulted windings, a simulation model of internal faults in salient pole synchronous machines is proposed in this paper. The model is based on the winding function approach, which makes no assumption for sinusoidal symmetrical distribution of the machine windings. A new method of calculation of synchronous machine inductances is presented, in which the space harmonics produced by the windings are readily taken into account. Simulation results for internal faults on the stator windings of a generator at no load and at load are compared with experimental results to verify the accuracy of the proposed model.
Keywords :
Internal faults , Synchronous machines , Winding function , Space harmonics
Journal title :
Mathematics and Computers in Simulation
Journal title :
Mathematics and Computers in Simulation