Title of article
Numerical analysis of the flow pattern in stented aneurysms and its relation to velocity reduction and stent efficiency Original Research Article
Author/Authors
Miki Hirabayashi، نويسنده , , Makoto Ohta، نويسنده , , Krisztina Bar?th، نويسنده , , Daniel A. Rufenacht، نويسنده , , Bastien Chopard، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
6
From page
128
To page
133
Abstract
We present a qualitative analysis of the flow pattern in cerebral aneurysms and the effect on the velocity reduction of stent implantation. We use the Lattice Boltzmann (LB) method, which implements a mesoscopic dynamics of the interactions between fictitious particles. LB provides an efficient numerical solver for complex boundary problems such as the flow in cerebral aneurysms. Several numerical and empirical studies show that the flow reduction mechanism of the stent in the saccular aneurysm is not simple to understand in detail. We have focused on the flow pattern in the aneurysm dome and shown that several characteristic properties allow to predict the effect of a treatment by a stent.
Keywords
Aneurysms , Stents , Computational fluid dynamics , Blood flow , Lattice Boltzmann method
Journal title
Mathematics and Computers in Simulation
Serial Year
2006
Journal title
Mathematics and Computers in Simulation
Record number
854454
Link To Document