Title of article :
X-ray spectrum generation for a multiphase flow meter
Author/Authors :
M.C.، Clarijs, نويسنده , , V.R.، Bom, نويسنده , , C.W.E.، van Eijk, نويسنده , , Z.I.، Kolar, نويسنده , , L.M.، Scheers, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
This paper describes the design of a geometry for the generation of X-rays to measure the relative amounts of oil, water, and gas in a flow. The measurement principle is based on the attenuation of X-rays in the mixture. The X-rays are generated by fluorescence in slanted foils placed in front of an end-window Xray tube. EGS4 Monte Carlo simulations have been used to determine an optimum geometry. We conclude that with an X-ray tube power in the order of only ~2.5 W, successful multiple energy X-ray absorption analysis should be possible.
Keywords :
Determination , Continuous , Cell immobilization , bioreactor , Biodegradable dissolved organic carbon
Journal title :
IEEE Transactions on Nuclear Science
Journal title :