Title of article :
The complexity of minimizing the number of shape matrices subject to minimal beam-on time in multileaf collimator field decomposition with bounded fluence Original Research Article
Author/Authors :
Thomas Kalinowski، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Pages :
16
From page :
2089
To page :
2104
Abstract :
The use of multileaf collimators (MLCs) is a modern way to realize intensity modulated fields in radiotherapy. An important step in the treatment planning is the shape matrix decomposition: the desired fluence distribution, given by an integer matrix, has to be decomposed into a small number shape matrices, i.e. image-matrices corresponding to the field shapes that can be delivered by the MLC used. The two main objectives are to minimize the total irradiation time, and the number of shape matrices. Assuming that the entries of the fluence matrix are bounded by a constant, we prove that a shape matrix decomposition with minimal number of shape matrices under the condition that the total irradiation time is minimal, can be determined in time polynomial in the matrix dimensions. The results of our algorithm are compared with Engel’s [K. Engel, A new algorithm for optimal multileaf collimator field segmentation, Discrete Appl. Math. 152 (1–3) (2005) 35–51.] heuristic for the reduction of the number of shape matrices.
Keywords :
Multileaf collimator , IMRT , Leaf sequencing , Radiation therapy optimization , Intensity modulation
Journal title :
Discrete Applied Mathematics
Serial Year :
2009
Journal title :
Discrete Applied Mathematics
Record number :
887147
Link To Document :
بازگشت