Title of article :
Diagnostics of direct CT - PT contact of the coolant channels of PHWRs Original Research Article
Author/Authors :
R.I.K. Moorthy، نويسنده , , J.K. Sinha، نويسنده , , A. Rama Rao، نويسنده , , S.K. Sinha، نويسنده , , Anil Kakodkar، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1995
Pages :
6
From page :
591
To page :
596
Abstract :
It has now been realised that the garter springs which maintain the gap between the pressure tube (PT) and calandria tube (CT) of a PHWR can get displaced significantly from their deign position in many channels. It has also been recognised that the large unsupported span of the PT restricts the life of the channel due to premature contact of the PT with the CT making it susceptible to delayed hydrogen cracking. This paper reports the details of a non-intrusive diagnostic technique based on vibration measurement for detecting the contacting channels.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
1995
Journal title :
Nuclear Engineering and Design Eslah
Record number :
887824
Link To Document :
بازگشت