Title of article :
An independent assessment of Groeneveld et al.ʹs 1995 CHF look-up table Original Research Article
Author/Authors :
Won Pil Baek، نويسنده , , Hong-Chae Kim، نويسنده , , Soon Heung Chang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
7
From page :
331
To page :
337
Abstract :
The prediction capability of the 1995 CHF look-up table (Groeneveld D.C., et al., Nucl. Eng. Des. 163 (1996) 1–23) is independently assessed based on the KAIST data base consisting of 10 822 data for uniformly-heated, vertical, round tubes. This confirms the error statistics for the heat balance method reported by Groeneveld et al. and shows overall average and RMS errors of 4.2 and 36.7%, respectively, for the direct substitution method. The new 1995 table shows better prediction capability than the 1986 AECL-UO table (), especially for the low-pressure, low-flow region. The error analysis indicates the length effect even for significantly long tubes.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
1997
Journal title :
Nuclear Engineering and Design Eslah
Record number :
888462
Link To Document :
بازگشت