Abstract :
In case of a failure of a coarse control arm (CCAs) at FRJ-2, reactivity is added to the reactor. The amount of this reactivity depends on the efficiency of the individual CCAs which has been measured as 180% of the average reactivity of the six arms for the central arm. For this design basis accident, it is required that only four out of five residual arms are capable of shutting down the reactor. This minimum shutdown reactivity is provided by an optimum fuel management including an experimental reactivity determination. Calculation of fuel burnup and material densities is performed by the depletion code SUSAN, which has been verified by separate calculations using ORIGEN. The difference in the reactivity values (between calculation and measurement) is mainly a consequence of the limitation of the inverse kinetic method, which is incapable of covering the effects of the flux deformation and interaction of the CCAs and core in the process of reactor scram.