Title of article :
Development of thermal fatigue testing apparatus with BWR water environment and thermal fatigue strength of austenitic stainless steels Original Research Article
Author/Authors :
Makoto Hayashi، نويسنده , , Kunio Enomoto، نويسنده , , Takashi Saito and Hidenobu Nunome ، نويسنده , , Toshiharu Miyagawa، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
10
From page :
113
To page :
122
Abstract :
A thermal fatigue testing apparatus was developed in order to clarify the fatigue behavior in BWR environment. Pressurized high and low temperature pure water were alternately supplied into an autoclave with a small cylindrical specimen. Then a fatigue specimen was subjected to homogeneous thermal stress through the wall thickness. Fatigue crack initiation behavior was observed with the replication method and compared with the mechanical fatigue strength performed in air and high temperature water. The thermal fatigue strength of type 304 and 316 nuclear grade (316NG) stainless steels agreed closely with the mechanical fatigue strength, when transforming the nominal stress amplitude to the fictitious stress amplitude by using the mean value of strain amplitudes for room temperature and 288°C.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
1998
Journal title :
Nuclear Engineering and Design Eslah
Record number :