Title of article :
Measurement of critical heat flux for narrow annuli submerged in saturated water Original Research Article
Author/Authors :
Soo Hyoung Kim، نويسنده , , Won Pil Baek، نويسنده , , Soon Heung Chang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
8
From page :
41
To page :
48
Abstract :
An experimental study has been performed to improve understanding of boiling phenomena and critical heat flux (CHF) in narrow gaps. The experiment has been performed with annular test sections submerged in a pool of saturated water under atmospheric pressure with the following conditions: outer diameter of inner tube of 19 mm; heated length of 200 mm; annular gap sizes of 0.5–3.5 mm, and inclination angles from horizontal to vertical positions. The experimental results reveal that the CHF increases with the gap size and the inclination angle. A one-dimensional two-phase model with a modified friction factor correlation is suggested to predict the CHF condition. The developed model is also compared with other CHF data.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2000
Journal title :
Nuclear Engineering and Design Eslah
Record number :
889142
Link To Document :
بازگشت