Title of article :
Critical heat flux under choking flow conditions: Part I – Outlet pressure fluctuations Original Research Article
Author/Authors :
A. Olekhnovitch، نويسنده , , A. Teyssedou، نويسنده , , P. Tye، نويسنده , , P. Champagne، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
15
From page :
159
To page :
173
Abstract :
Under conditions of forced convective boiling at low pressures and high mass fluxes, beyond a certain quality, choking flow may occur at the exit of a heated channel. An experimental investigation of the influence of this phenomenon on the critical heat flux (CHF) has been carried out. An analysis of the pressure distribution downstream of the heated length as well as the behaviour of the wall temperature during CHF has shown that the occurrence of choking flow, namely outlet pressure fluctuations, does not radically influence the values of the CHF. The physical reasons for the appearance of these outlet pressure fluctuations under conditions of diabatic choking flow have been analyzed. The experimental investigation has also shown that when choking flow occurs the outlet pressure cannot be lowered below a certain value that is fixed by the flow itself. The maximum values of flow parameters attained under choking flow conditions are presented in the Part II of this paper.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2001
Journal title :
Nuclear Engineering and Design Eslah
Record number :
889307
Link To Document :
بازگشت