Title of article :
Primary water stress corrosion cracking behaviors in the shot-peened Alloy 600 TT steam generator tubings Original Research Article
Author/Authors :
In-Gyu Park، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
5
From page :
395
To page :
399
Abstract :
The effect of compressive residual stress on the primary water stress corrosion cracking behavior was investigated, based on the J-1 and J-2 nuclear power plant data. The following analyses were performed such as: (i) Weibull slope; (ii) crack growth rate; (iii) average crack length; (iv) crack length distribution. Alloy 600 TT exhibits strong heat to heat variations in its sensitivity to PWSCC. Crack growth rate was retarded after shot-peening. The compressive residual stress induced by shot-peening was more effective on new, short cracks, than on existing, long cracks. However, whether the ‘new’ cracks were initiated after peening is an unresolved issue, due to the present ECT sensitivity limit.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2002
Journal title :
Nuclear Engineering and Design Eslah
Record number :
889497
Link To Document :
بازگشت