Title of article
Structural design and two-phase flow stability test for the steam generator Original Research Article
Author/Authors
Li Rizhu، نويسنده , , Ju Huaiming، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
9
From page
179
To page
187
Abstract
This paper describes the structural designs and the two-phase flow stability test for the steam generator of the 10 MW high temperature gas-cooled reactor test module. The sectionalized heat transfer surface of the steam generator is made up of modules formed by series-connected single cylindrical coils wound around a displacer. Such a heating surface has some advantages as compared with a heating surface formed by multi concentric coils with a great diameter of winding (Proceeding of the International ANS/ENS Topical Meeting on Thermal Reactor Safety (1986); Progress of HTGR Process Heat Application Study (1994); Heat Transfer-Soviet Res. 22 (1990)). It plays an important part in the design of the integrated steam generator. Since it is a once-through steam generator and operates at a medium pressure (4.0 MPa), two-phase flow instabilities are a difficult problem (Functional Performance of the Helical Coil SG CNSG-IV System (1975)). The design must eliminate two-phase flow instabilities and the system must be tested to show that flow instability does not occur.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2002
Journal title
Nuclear Engineering and Design Eslah
Record number
889621
Link To Document