Title of article :
COCOSYScodevalidationagainstmeasureddataduringunintendedsinglemainsafetyvalveopeningatIgnalinaNPPOriginalResearchArticle
Author/Authors :
E.Urbonavicius، نويسنده , , S.Rimkevicius، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
TheanalysisofanunintendedmainsafetyvalveopeningatIgnalinaNPPwasperformedwithCOCOSYScodeinordertoassessitscapabilityinsimulationofthetransientprocessesthatoccurinsideAccidentLocalisationSystemofIgnalinaNPP.COCOSYShasseveraluser-selectedoptions,e.g.zonemodel(EQUIL._MOD,NONEQUILIB),waterflowmodel(BAL_DRAIN,DRAIN_BOT),etcfornodalisationdevelopment.Theinfluenceofazonemodelselection,awateroverflowmodelselectionandefficiencyofheatexchangerinCondenserTrayCoolingSystemwasinvestigatedandpresentedinthepaper.TheperformedanalysissupportedintroductionofnewwateroverflowmodelinCOCOSYScodeandshowedthatCOCOSYScodecanbeappliedfortheanalysisofAccidentLocalisationSystemofIgnalinaNPP.
Journal title :
Nuclear Engineering and Design Eslah
Journal title :