  • Abstract
    AninvestigationofthethermalhydrauliccharacteristicsinthepassiveresidualheatremovalsystemoftheSystemintegratedModularAdvancedReacTor-P(SMART-P)hasbeencarriedoutusingtheMARScode,whichisabestestimatesystemanalysiscode.TheSMART-Pisdesignedtocoolthesystemduringaccidentalconditionsbyanaturalconvection.Thedominantheattransferinthesteamgeneratorisaboilingmodeunderaforcedconvectioncondition,anditisasingle-phaseliquidandaboilingheattransferunderanaturalconvectioncondition.Mostoftheheatisremovedintheheatexchangerofthepassiveresidualheatremovalsystembyacondensationheattransfer.Thepassiveresidualheatremovalsystemcanremovetheenergyfromtheprimarysideaslongastheheatexchangerissubmergedintherefuelingwatertank.Themassflowisstableunderanaturalcirculationconditionthoughitoscillatesperiodicallywithasmallamplitude.Theparameterstudyisperformedbyconsideringtheeffectsofaneffectiveheightbetweenthesteamgeneratorandtheheatexchanger,ahydraulicresistance,aninitialpressure,anon-condensablegasfractioninthecompensatingtank,andavalveactuationtime,whichareusefulforthedesignofthepassiveresidualheatremovalsystem.Themassflowinthepassiveresidualheatremovalsystemhasbeenaffectedbytheheightbetweenthesteamgeneratorandtheheatexchanger,andthehydraulicresistanceoftheloop.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2004
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    894795