• Title of article

    Measurement of supercritical CO2 critical flow: Effects of L/D and surface roughness Original Research Article

  • Author/Authors

    Guillaume P. Mignot، نويسنده , , Mark H. Anderson، نويسنده , , Michael L. Corradini، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    7
  • From page
    949
  • To page
    955
  • Abstract
    The use of supercritical fluids (SCF) has been proposed for advanced power systems including advanced sodium reactors, since these fluids can provide higher thermal efficiency and reduced system component size. Data characterizing the behavior of SCF during a blowdown or rapid depressurization are essential to validate certain aspects of safety analyses. This paper describes the results of an experiment to measure the critical mass flux for numerous stagnation thermodynamic conditions, geometry and outlet tube roughness. It was found that a 1D homogeneous equilibrium model (HEM) was capable of relatively good (less than 10% error) prediction of the test data.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2009
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    895306