• Title of article

    Actual flow calibration of a feedwater flowmeter using a high Reynolds number facility at NMIJ Original Research Article

  • Author/Authors

    Noriyuki Furuichi، نويسنده , , Yoshiya Terao، نويسنده , , Masaki Takamoto، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2009
  • Pages
    10
  • From page
    1304
  • To page
    1313
  • Abstract
    The results of calibration tests of the feedwater flowrate of ultrasonic flowmeters used in a nuclear power plant for variety of upstream conditions obtained using the new high Reynolds number calibration facility at NMIJ are described. In this examination, the measurements are performed for five pattern pipe layouts with one or two elbows. The flow conditioners installed upstream of the flowmeter are the tube bundle type and the Mitsubishi, which are normally used in nuclear power plants. The calibration result for each flowmeter are largely different for each flow conditioner and each upstream pipe layout, except in some special cases. Moreover, the trend of the correction factor with Reynolds number is not uniform for each case. Furthermore, some differences were observed for individual flowmeters. It is recommended that the feedwater flowmeter, especially when used to perform measurement uncertainty recapture, is calibrated based on the actual pipe layout and the Reynolds number corresponding to the actual nuclear power plant conditions.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2009
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    895343