Title of article
Fluid dynamic interaction between water hammer and centrifugal pumps Original Research Article
Author/Authors
A. Ismaier، نويسنده , , E. Schlücker، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2009
Pages
4
From page
3151
To page
3154
Abstract
Centrifugal pumps generate in piping systems noticeable pressure pulsations. In this paper the dynamic interaction between water hammer and pressure pulsations is presented. The experimental investigations were performed at a piping system with nominal diameter DN 100 (respectively NPS 4) and 75 m total length, built at the Institute for Process Technology and Machinery. Different measurements at this testing facility show that pulsating centrifugal pumps can damp pressure surges generated by fast valve closing. It is also shown that 1-dimensional fluid codes can be used to calculate this phenomenon. Furthermore it is presented that pressure surges pass centrifugal pumps almost unhindered, because they are hydraulic open.
Journal title
Nuclear Engineering and Design Eslah
Serial Year
2009
Journal title
Nuclear Engineering and Design Eslah
Record number
895522
Link To Document