Title of article :
Jet-plume condensation of steam–air mixtures in subcooled water, Part 1: Experiments Original Research Article
Author/Authors :
Timothy L. Norman، نويسنده , , Shripad T. Revankar and Doug Pollock، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
9
From page :
524
To page :
532
Abstract :
A scaled-down, reduced pressure suppression pool was designed to study condensation and mixing phenomena for a LOCA (loss of coolant accident) event in a SBWR (simplified boiling water reactor) design. The scaled-down test facility represented an idealized trapezoidal cross-section, 1/10 sector of the SP (suppression pool) with scaled height ratio of 1/4.5 and volume ratio of 1/400. The facility was instrumented with thermocouples for pool temperature measurements and a high-speed camera for flow visualization. Thermal stratification data were obtained for different pool initial subcooling and steam–air mixture flow rates. A dimensionless boundary map was derived from several experimental runs of pure steam injection to determine conditions when the pool transitions from being a homogeneously mixed volume to being a thermally stratified one. Steam air mixture injection cases for single horizontal venting indicated that above a pool temperature of 40 °C with air mass fraction below 0.5% the pool can attain thermal stratification.
Journal title :
Nuclear Engineering and Design Eslah
Serial Year :
2010
Journal title :
Nuclear Engineering and Design Eslah
Record number :
895582
Link To Document :
بازگشت