• Title of article

    Optimumlocalfailuremodelofsteamgeneratortubeswithmultipleaxialthrough-wallcracksOriginalResearchArticle

  • Author/Authors

    SeongInMoon، نويسنده , , YoungJinKim، نويسنده , , JinHoLee، نويسنده , , YounWonPark، نويسنده , , MyungHoSong، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    10
  • From page
    2099
  • To page
    2108
  • Abstract
    Itiscommonlyrequiredthatsteamgeneratortubeswall-thinnedinexcessof40%shouldbeplugged.However,thepluggingcriteriaareknowntobetooconservativeforsomelocationsandtypesofdefectsanditsapplicationisconfinedtoasinglecrack.Inthepreviousstudy,acrackcoalescencemodelapplicabletosteamgeneratortubeswithtwocollinearaxialthrough-wallcrackswasproposedandacoalescenceevaluationdiagramwasdevelopedwhichcanbeusedtodeterminewhethertheadjacentcracksdetectedbyNDEcoalesceornot.Inthispaper,atotalof9localfailuremodelsincludingflowstressmodel,necking-basedmodel,stress-basedmodel,reactionforcemodelandplasticzonecontactmodelwereintroducedtodeterminetheoptimumlocalfailuremodel.Plasticcollapsetestsandfiniteelementanalysesusingthinplateswithtwocollinearthrough-wallcrackswereperformedfortheselectionoftheoptimumlocalfailuremodel.Bycomparingthetestresultswiththepredictionresultsobtainedfromlocalfailuremodels,thereactionforcemodelandplasticzonecontactmodelweredeterminedastheoptimumlocalfailuremodels.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2005
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    895931