Title of article :
P erformance analysis of a solar-assisted heat pump water heater
Author/Authors :
J.P. Chyng، نويسنده , , C.P. Lee، نويسنده , , B.J. Huang، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2003
Abstract :
A modeling and system simulation of an integral-type solar assisted heat pump water heater (ISAHP) was carried out in
the present study. The modeling and simulation assumes a quasi-steady process for all the components in the ISAHP except
the storage tank. The simulation results for instantaneous performance agreed very well with experiment. The simulation
technique was used to analyze the daily performance of an ISAHP for 1 year. It is shown that the daily total COP (COP ) is o
around 1.7 to 2.5 year around for the ISAHP, depending on seasons and weather conditions. COP is higher than 2.0 for most o
of the time in a year and the daily operating time varies from 4 to 8 h. The online adjustment requirement of the expansion
valve was also investigated using the present simulation technique. The analysis shows that the expansion device does not
need to be controlled online. Using the 1-year simulation results, a universal daily performance correlation of the ISAHP was
derived and shown experimentally to be applicable to another design of ISAHP.
2003 Elsevier Science Ltd. All rights reserved.
Journal title :
Solar Energy
Journal title :
Solar Energy