  • Abstract
    The salt gradient solar pond is a long-term heat storage system with a considerable warm-up time. A pond is efficient when it reaches the desired temperature quickly and maximum heat is subsequently retrieved at steady state. This requires optimum sizing of the non-convective zone. In the present work, the optimum size of the non-convective zone for fast warm-up is determined. This is found to differ considerably from the optimum size of the steady state criterion. The possibility of achieving both performance parameters, i.e. fast warm-up and maximum heat collection later on, is analyzed. It is suggested that when commissioning a pond, the size of the non-convective zone should at first be the optimum value from the warm-up rate criterion, but may later be changed to the optimum size from the steady state criterion.  2003 Elsevier Ltd. All rights reserved