Title of article :
O ptimum size of non-convective zone for improved thermal
performance of salt gradient solar pond
Author/Authors :
M. Husain، نويسنده , , P.S. Patil، نويسنده , , S.R. Patil، نويسنده , , S.K. Samdarshi، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2003
Abstract :
The salt gradient solar pond is a long-term heat storage system with a considerable warm-up time. A pond is efficient
when it reaches the desired temperature quickly and maximum heat is subsequently retrieved at steady state. This requires
optimum sizing of the non-convective zone. In the present work, the optimum size of the non-convective zone for fast
warm-up is determined. This is found to differ considerably from the optimum size of the steady state criterion. The
possibility of achieving both performance parameters, i.e. fast warm-up and maximum heat collection later on, is analyzed. It
is suggested that when commissioning a pond, the size of the non-convective zone should at first be the optimum value from
the warm-up rate criterion, but may later be changed to the optimum size from the steady state criterion.
2003 Elsevier Ltd. All rights reserved
Journal title :
Solar Energy
Journal title :
Solar Energy