Abstract
The use of ventilated facades and roofs can help to reduce summer thermal loads and, therefore, the energy consumption
due to air-conditioning systems. This paper discusses a simple analytical method for the calculation of the
energy saving achievable by using ventilated facades in which the air flow inside the air duct is due to stack effect. Two
particular cases of outstanding importance are investigated. The first in which the inner masonry wall is given, and the
air duct and the outer facing have to be optimized. The second in which the outer facing is given, and the inner masonry
wall and the air duct have to be optimized. The first case can occur in existing buildings renovation, while the second
case can occur during the design process. Finally, the influence of the variation of some quantities necessary for calculation
on the energy performance of ventilated facades is investigated. In particular, the energy performance of such
facades results to be strongly influenced by the air duct width, the insulating material distribution, the solar radiation
intensity, the wall outer surface thermal resistance and the roughness of the slabs delimiting the air duct.