• Title of article

    An exergy analysis of a solar-driven ejector refrigeration system

  • Author/Authors

    Wimolsiri Pridasawas *، نويسنده , , Per Lundqvist، نويسنده ,

  • Issue Information
    دوماهنامه با شماره پیاپی سال 2004
  • Pages
    11
  • From page
    369
  • To page
    379
  • Abstract
    Exergy analysis is used as a tool to analyse the performance of an ejector refrigeration cycle driven by solar energy. The analysis is based on the following conditions: a solar radiation of 700 W/m2, an evaporator temperature of 10 C, a cooling capacity of 5 kW, butane as the refrigerant in the refrigeration cycle and ambient temperature of 30 C as the reference temperature. Irreversibilities occur among components and depend on the operating temperatures. The most significant losses in the system are in the solar collector and the ejector. The latter decreases inversely proportional to the evaporation temperature and dominates the total losses within the system. The optimum generating temperature for a specific evaporation temperature is obtained when the total losses in the system are minimized. For the above operating conditions, the optimum generating temperature is about 80 C. 2003 Elsevier Ltd. All rights reserved.
  • Keywords
    Solar cooling , Ejector , Exergy
  • Journal title
    Solar Energy
  • Serial Year
    2004
  • Journal title
    Solar Energy
  • Record number

    939295