• Title of article

    Performance of a concentrating photovoltaic/thermal solar collector

  • Author/Authors

    Joe S. Coventry *، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2005
  • Pages
    12
  • From page
    211
  • To page
    222
  • Abstract
    The performance of a parabolic trough photovoltaic/thermal collector with a geometric concentration ratio of 37· is described. Measured results under typical operating conditions show thermal efficiency around 58% and electrical efficiency around 11%, therefore a combined efficiency of 69%. The impact of non-uniform illumination on the solar cells is investigated using purpose built equipment that moves a calibrated solar cell along the line of the receiver and measures short circuit current. The measured illumination flux profile along the length shows significant variation, despite the mirror shape error being less than 1 mm for most of the mirror area. The impact of the illumination nonuniformities due to the shape error, receiver support post shading and gaps between the mirrors is shown to have a significant effect on the overall electrical performance. The flux profile transverse to the receiver length is also investigated. Peak flux intensities are shown to be around 100 suns. The impact on efficiency due to open circuit voltage reduction is discussed. 2004 Elsevier Ltd. All rights reserved.
  • Journal title
    Solar Energy
  • Serial Year
    2005
  • Journal title
    Solar Energy
  • Record number