Title of article
Performance improvement by discharge from different levels in solar storage tanks
Author/Authors
Simon Furbo، نويسنده , , Elsa Andersen، نويسنده , , Alexander Thu¨ r، نويسنده , , Louise Jivan Shah *، نويسنده , , Karin Dyhr Andersen، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2005
Pages
9
From page
431
To page
439
Abstract
The thermal advantages by utilizing discharge from different levels in solar storage tanks are investigated, both for a
small SDHW system and for a solar combisystem.
The investigations showed that it is possible to increase the thermal performance of both types of systems by using
two draw-off levels from the solar tanks instead of one draw-off level at a fixed position.
The best position of the second draw-off level is in the middle or just above the middle of the tank. For the investigated
small SDHW system with a realistic draw off hot water temperature of 40 C and 45 C and an auxiliary volume
temperature of 50.5 C the increase of the thermal performance by the second draw-off level is about 6%.
For the investigated solar combisystem the increase in thermal performance by using one extra draw-off level, either
for the domestic hot water heat exchanger or for the heating system, is about 3%, while an improvement of about 5% is
possible by using a second draw-off level both for the domestic hot water heat exchanger and for the heating system.
2005 Elsevier Ltd. All rights reserved
Keywords
SDHW systems , Thermal stratification , Advanced discharge strategies , Heat storage tanks , Solar combisystems