Abstract
Supply air windows under optimum flow conditions function as an efficient heat reclaim device. Heat escaping from
the room, through the inner glass pane, is entrained in the air flow between the inner and outer sashes and returned to
the room. A low-E coating to the inner glass acts as a barrier to radiation heat loss across the window so very low
U-values can be achieved. These same characteristics enable the window to function as a passive solar component.
Its efficiency is inferior to that of a dedicated passive solar device due to its transparency, but even so at modest levels
of incident solar gain a worthwhile proportion is entrained into the air flow and supplied to the rooms as pre-heated
ventilation air supply. These characteristics have been established by laboratory, test cell investigations, and simulations
using computational fluid dynamics and ESP-r, a whole building dynamic thermal modelling tool.