• Title of article

    Determination of the AC losses of Bi-2223 HTS coils at 77 K at power frequencies using a mass boil-off calorimetric technique

  • Author/Authors

    F.، Darmann, نويسنده , , Dou، Shi نويسنده , , C.، Cook, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    0
  • From page
    1
  • To page
    0
  • Abstract
    A mass boil-off measurement system has been used to accurately measure and characterize the ac loss of high-temperature superconductor (HTS) coils at frequencies between 50 and 200 Hz, and in applied ac fields of up to 0.04 T. The mass boil-off calorimeter incorporated a glass cryostat, a copper field coil, and two mass flow meters. The response of the gas flow to a step change in the applied magnetic field was found to have a time constant of about 600 s. Under suitable experimental conditions, it was possible to measure the ac losses of coils with an accuracy of +-0.3 W. The ac loss characteristics of an HTS pancake and two HTS solenoid coils are presented and the accuracy of mass flow calorimetry in liquid nitrogen is reported on.
  • Keywords
    Patients
  • Journal title
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
  • Serial Year
    2003
  • Journal title
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY
  • Record number

    93966