Title of article
Performance study on a structured packed liquid desiccant regenerator
Author/Authors
Esam Elsarrag، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2006
Pages
8
From page
1624
To page
1631
Abstract
The solution carryover in traditional desiccant regeneration towers is of serious concern in real applications especially
when using triethylene glycol (TEG) as a desiccant. In this study, the cellulose rigid media pads are used as the structured
packing. The packing arrangements have provided minimum carryover of TEG. A performance study of the simultaneous
heat and mass transfer between air and desiccant in a structured packed-stripping tower is conducted. Through the study
of the regenerator, important design variables are defined and the regenerator performance is compared with the previous
studies. The effects of air and liquid flow rates, air humidity, desiccant temperature and desiccant concentration have been
reported on the evaporation rate and humidity effectiveness of the column. It is found that high liquid flow rates do not
have a significant effect on the performance variables.
2006 Elsevier Ltd. All rights reserved.
Keywords
desiccant , Packing , regeneration
Journal title
Solar Energy
Serial Year
2006
Journal title
Solar Energy
Record number
939735
Link To Document