Title of article :
Effect of load pattern on solar-boosted heat pump
water heater performance
Author/Authors :
T.N. Anderson *، نويسنده , , G.L. Morrison، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2007
Abstract :
The performance of a solar-boosted heat pump water heater (HPWH) operating under full load and part load conditions was determined
in an outdoor experimental study. The system utilised flat unglazed aluminium solar evaporator panels to absorb solar and ambient
energy. Absorbed energy was transferred to the water tank by means of the heat pump and a wrap around condenser coil on the
outside of the tank. The system COP was found to be in the range of 5–7 under clear daytime conditions and 3–5 under clear night-time
conditions. Using part load testing of the HPWH system it was found that concentrating the coils in the lower portion of the tank could
increase the efficiency of the condenser coil. It was also shown that there exists a generalised linear relationship that can be used to
describe the system COP in terms of the temperature difference between the water in the storage tank and the ambient air.
2007 Elsevier Ltd. All rights reserved
Keywords :
Heat pump , Water heater
Journal title :
Solar Energy
Journal title :
Solar Energy