Title of article
Experimental study of effect of an inner thermal curtain in evaporative cooling system of a cascade greenhouse
Author/Authors
Ashish Shukla، نويسنده , , G.N. Tiwari، نويسنده , , M.S. Sodha، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2008
Pages
12
From page
61
To page
72
Abstract
In this paper experimental study has been carried out in a cascade greenhouse with inner thermal curtain to see the effect of thermal
curtain. A thermal model has also been developed to predict the air temperature in a cascade greenhouse. The fan-pad system has been
used for evaporative cooling and an inner thermal curtain has been used to divide the greenhouse in two zones. Experiments have been
conducted in hot summer conditions at Solar Energy Park, IIT Delhi, New Delhi, India for empty greenhouse. Statistical analysis has
been carried out to validate the agreement of experimental observations with predicted values. The values of the root mean square percent
deviation and coefficient of correlation has been found out 9.0%, 0.90; 5.0%, 0.95 and 7.0%, 0.97 for April, May and June in case of
evaporative cooling without curtain in greenhouse-2. The degree of freedom for the experimental work is 10.0. It is found that the use of
evaporative cooling with a thermal curtain reduces the temperature of greenhouse by 5 C and 8 C in the second zone of greenhouse-1
and 2 in comparison to greenhouse without curtain in May.
2007 Elsevier Ltd. All rights reserved.
Keywords
Thermal curtain , Cascade greenhouse , Evaporative cooling
Journal title
Solar Energy
Serial Year
2008
Journal title
Solar Energy
Record number
939889
Link To Document