Title of article
Urban heat island intensity in London: An investigation of the impact of physical characteristics on changes in outdoor air temperature during summer
Author/Authors
Maria Kolokotroni *، نويسنده , , Renganathan Giridharan، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2008
Pages
13
From page
986
To page
998
Abstract
The study looks at the potential of physical characteristics in mitigating the urban heat island intensity (UHI) in London during summer.
This research uses six on-site variables namely aspect ratio, surface albedo, plan density ratio, green density ratio, fabric density
ratio and thermal mass for the investigation in six data sets. The climatic variations in summer are controlled by classifying the data
into clear sky, partially cloudy and cloudy periods. Geographical variation is controlled by classifying the data into core, urban and semi
urban areas. Maximum daytime UHI of 8.9 C is found in semi-urban area during partially cloudy period while maximum nocturnal
UHI of 8.6 C is found in urban area during clear sky period when the wind velocity is below 5 m/s. The most critical climate and geographical
location in determining the changes in outdoor air temperature in London are partially cloudy periods and urban areas respectively.
Among the variables studied, most critical variable that determines the daytime and nocturnal changes in outdoor air temperature
is surface albedo.
2008 Elsevier Ltd. All rights reserved
Keywords
core , Sky cloud conditions , urban , Semi-urban , On-site variables , Urban heat island intensity (UHI)
Journal title
Solar Energy