Title of article
Discharge of a thermal storage tank using an immersed heat exchanger with an annular baffle
Author/Authors
Julia F. Haltiwanger، نويسنده , , Jane H. Davidson، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
9
From page
193
To page
201
Abstract
A number of solar domestic hot water systems and many combined space and water heating systems have heat exchangers placed
directly in the storage fluid to charge and/or discharge the tank. Operation of the heat exchanger produces a buoyancy-driven flow within
the storage fluid. With a view toward controlling the flow field to increase heat transfer, a cylindrical baffle is inserted in a 350 l cylindrical
storage tank. The baffle creates a 40 mm annular gap adjacent to the tank wall. A 10 m-long, 0.3 m2 copper coil heat exchanger is placed
in the gap. The effects of the baffle on the transient heat transfer, delivered water temperature, heat exchanger effectiveness, and temperature
distribution within the storage fluid are presented during discharge of initially thermally stratified and fully mixed storage tanks.
The baffle increases the storage side convective heat transfer to the heat exchanger by 20%. This increase is attributed to higher storage
fluid velocities across the heat exchanger.
2008 Elsevier Ltd. All rights reserved.