Title of article
Estimation of internal heat transfer coefficients of a hybrid (PV/T) active solar still
Author/Authors
Shiv Kumar، نويسنده , , G.N. Tiwari، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2009
Pages
12
From page
1656
To page
1667
Abstract
In this paper, an attempt is made to estimate the internal heat transfer coefficients of a deep basin hybrid (PV/T) active solar still. The estimation is based on outdoor experimental observation of hybrid (PV/T) solar still for composite climate of New Delhi (latitude 28°35′N and longitude 77°12′E). The internal heat transfer coefficients are evaluated by using thermal models proposed by various researchers. The comparison of hourly yield predicted using various thermal models to the experimental has also been carried out by evaluating the correlation coefficient and percentage deviation. It is observed that, Kumar and Tiwari model (KTM) better validate the results than the others model. The average annual values of convective heat transfer coefficient for the passive and hybrid (PV/T) active solar still are observed as 0.78 and 2.41 W m−2 K−1, respectively at 0.05 m water depth.
Keywords
Hybrid (PV/T) active solar still , Internal heat transfer coefficients , validation
Journal title
Solar Energy
Serial Year
2009
Journal title
Solar Energy
Record number
940158
Link To Document