• Title of article

    Thermal response of a series- and parallel-connected solar energy storage to multi-day charge sequences

  • Author/Authors

    Cynthia A. Cruickshank، نويسنده , , Stephen J. Harrison، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2011
  • Pages
    8
  • From page
    180
  • To page
    187
  • Abstract
    The thermal response of a multi-tank thermal storage was studied under variable charge conditions. Tests were conducted on an experimental apparatus that simulated the thermal charging of the storage system by a solar collector over predetermined (prescribed) daylong periods. The storage was assembled from three standard 270 L hot-water storage tanks each charged through coupled, side-arm, natural convection heat exchangers which were connected in either a series- or parallel-flow configuration. Both energy storage rates and tank temperature profiles were experimentally measured during charge periods representative of two consecutive clear days or combinations of a clear and overcast day. During this time, no draw-offs were conducted. Of particular interest was the effect of rising and falling charge-loop temperatures and collector-loop flow rate on storage tank stratification levels. Results of this study show that the seriesconnected thermal storage reached high levels of temperature stratification in the storage tanks during periods of rising charge temperatures and also limited destratification during periods of falling charge temperature. This feature is a consequence of the series-connected configuration that allowed sequential stratification to occur in the component tanks and energy to be distributed according to temperature level. This effect was not observed in the parallel charge configuration. A further aspect of the study investigated the effect of increasing charge-loop flow rate on the temperature distribution within the series-connected storage and showed that, at high flow rates, the temperature distributions were found to be similar to those obtained during parallel charging. A disadvantage of both the high-flow series-connected and parallel-connected multi-tank storage is that falling charge-loop temperatures, which normally occur in the afternoon, tend to mix and destratify the storage tanks. 2010 Elsevier Ltd. All rights reserved.
  • Keywords
    thermal energy storage , Multi-tank , Solar hot water1. IntroductionEfficient and cost effective thermal storage is importantin the design of solar thermal systems. Water storage tanksare particularly well suited to this task and readily availablein small volumes , being widely used in domestic hot watersystems. As the size of solar systems increase , however , largerstorages are , thermal stratification , Solar heating systems
  • Journal title
    Solar Energy
  • Serial Year
    2011
  • Journal title
    Solar Energy
  • Record number