• Title of article

    Automated high resolution measurement of heliostat slope errors

  • Author/Authors

    Steffen Ulmer، نويسنده , , *، نويسنده , , Tobias Ma¨rz a، نويسنده , , Christoph Prahl a، نويسنده , , Wolfgang Reinalter a، نويسنده , , Boris Belhomme b، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2011
  • Pages
    7
  • From page
    681
  • To page
    687
  • Abstract
    A new optical measurement method that simplifies and optimizes the mounting and canting of heliostats and helps to assure their optical quality before commissioning of the solar field was developed. This method is based on the reflection of regular patterns in the mirror surface and their distortions due to mirror surface errors. The measurement has a resolution of about 1 million points per heliostat with a measurement uncertainty of less than 0.2 mrad and a measurement time of about 1 min per heliostat. The system is completely automated and allows the automatic measurement of an entire heliostat field during one night. It was extensively tested at the CESA-1 heliostat field at the Plataforma Solar de Almerı´a. Comparisons of flux simulations based on the measurement results with real flux density measurements were performed. They showed an excellent agreement and demonstrated in a striking manner the high measurement accuracy and high grade of detail in the simulation achieved by this technique. 2010 Elsevier Ltd. All rights reserved
  • Keywords
    Heliostat , optical measurement , deflectometry , Optical quality , Ray tracing , Flux measurement
  • Journal title
    Solar Energy
  • Serial Year
    2011
  • Journal title
    Solar Energy
  • Record number