• Title of article

    Effects of solar photovoltaic panels on roof heat transfer

  • Author/Authors

    Anthony Dominguez a، نويسنده , , Jan Kleissl *، نويسنده , , ?، نويسنده , , Jeffrey C. Luvall b، نويسنده ,

  • Issue Information
    ماهنامه با شماره پیاپی سال 2011
  • Pages
    12
  • From page
    2244
  • To page
    2255
  • Abstract
    Indirect benefits of rooftop photovoltaic (PV) systems for building insulation are quantified through measurements and modeling. Measurements of the thermal conditions throughout a roof profile on a building partially covered by solar photovoltaic (PV) panels were conducted in San Diego, California. Thermal infrared imagery on a clear April day demonstrated that daytime ceiling temperatures under the PV arrays were up to 2.5 K cooler than under the exposed roof. Heat flux modeling showed a significant reduction in daytime roof heat flux under the PV array. At night the conditions reversed and the ceiling under the PV arrays was warmer than for the exposed roof indicating insulating properties of PV. Simulations showed no benefit (but also no disadvantage) of the PV covered roof for the annual heating load, but a 5.9 kWh m 2 (or 38%) reduction in annual cooling load. The reduced daily variability in rooftop surface temperature under the PV array reduces thermal stresses on the roof and leads to energy savings and/or human comfort benefits especially for rooftop PV on older warehouse buildings. 2011 Elsevier Ltd. All rights reserved
  • Keywords
    Building energy use , Cooling load , Photovoltaic , Thermal Infrared Camera , Roof heat flux
  • Journal title
    Solar Energy
  • Serial Year
    2011
  • Journal title
    Solar Energy
  • Record number