Title of article :
Numerical calculation of series and shunt resistance of a photovoltaic cell using the Lambert W-function: Experimental evaluation
Author/Authors :
F. Ghani ?، نويسنده , , b، نويسنده , , ?، نويسنده , , M. Duke a، نويسنده , , J. Carson a، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2013
Pages :
8
From page :
246
To page :
253
Abstract :
The values of series and shunt resistances play an important role in the modelling behaviour of a photovoltaic cell. The authors proposed in earlier work a new method to determine these values numerically at maximum power point using the Newton–Raphson method and equations based on the Lambert W-function. Here, an experimental investigation has been carried out to further validate this method and observe its behaviour over the entire current–voltage curve. Current–voltage curves from a single multi-crystalline cell were obtained under outdoor testing in Hamilton, New Zealand under three levels of illumination (800, 900, and 1000 W/m2). In addition to the method of Ghani and Duke (2011), two other methods were also used to calculate series and shunt resistances based on the parameters extracted from the experimental data. A comparative study of each methods output current vector using a root mean square error analysis revealed that greatest accuracy was achieved with the proposed approach. 2012 Elsevier Ltd. All rights reserved
Keywords :
Series resistance , Shunt resistance , Numerical calculation , Lambert W-function , Photovoltaic parameters , Solar modelling
Journal title :
Solar Energy
Serial Year :
2013
Journal title :
Solar Energy
Record number :
941209