• Title of article

    SCALE calculation for evaluation of spent fuel condition during long-term storage Original Research Article

  • Author/Authors

    M. Miklo?، نويسنده , , V. Sluge?، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    4
  • From page
    2811
  • To page
    2814
  • Abstract
    Experiences with an advanced spent nuclear fuel management in Slovakia are presented in this paper. The evaluation and monitoring procedures are based on practices at the Slovak wet interim spent fuel storage facility in NPP Jaslovské Bohunice. Since 1999, leak testing of WWER-440 fuel assemblies were completed using a special leak tightness detection system developed by Framatome-anp, “Sipping in Pool”. This system utilized external heating for the precise defects determination. Optimal methods for spent fuel disposal and monitoring were designed. A new conservative factor for specifying of spent fuel leak tightness is introduced in the paper. Limit values of leak tightness were established from the combination of SCALE4.4a (ORIGEN-ARP) calculations and measurements from the “Sipping in Pool” system. These limit values are: limiting fuel cladding leak tightness coefficient for tight fuel assembly – kFCT(T) = 3 × 10−10, limiting fuel cladding leak tightness coefficient for fuel assembly with leakage – kFCT(L) = 8 × 10−7.
  • Journal title
    Nuclear Engineering and Design Eslah
  • Serial Year
    2008
  • Journal title
    Nuclear Engineering and Design Eslah
  • Record number

    941527