Author/Authors :
A.V.، Zlobin, نويسنده , , N.، Andreev, نويسنده , , E.، Barzi, نويسنده , , S.، Yadav, نويسنده , , S.، Bhashyam, نويسنده , , C.، Boffo, نويسنده , , D.R.، Chichili, نويسنده , , I.، Terechkine, نويسنده ,
Abstract :
To provide a quick feedback on different approaches to superconducting cable splicing design and assembly techniques, a superconducting current transformer that can deliver more than 20 kA for testing splice samples was designed and fabricated. The existing infrastructure of the Short Sample Test Facility at Fermilab, including its cryostat, power supply, and data acquisition system, was used for housing and operating the transformer. This report presents the design features of the transformer and the main results of cable splice tests.