Title of article :
First performance test of the cryogenfree hybrid magnet
Author/Authors :
K.، Watanabe, نويسنده , , K.، Takahashi, نويسنده , , G.، Nishijima, نويسنده , , S.، Awaji, نويسنده , , M.، Motokawa, نويسنده , , K.، Jikihara, نويسنده , , M.، Ishizuka, نويسنده , , J.، Sakuraba, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
-1631
From page :
1632
To page :
0
Abstract :
We are now constructing a cryogenfree 23 T hybrid magnet at the High Field Laboratory for Superconducting Materials, Institute for Materials Research, Tohoku University. At present, an outer section coil employing NbTi multifilamentary wires for a cryogenfree superconducting magnet of the hybrid magnet was combined with an inner 15.5 T water-cooled resistive magnet, and was tested as the worldʹs first cryogenfree hybrid magnet. The NbTi coil with 491 mm inner diameter and 584 mm outer diameter generated 4.59 T at 198 A, and the central magnetic field of 20.0 T was generated in a 52 mm room temperature experimental bore. The magnetic force field of 2030 T/sup 2//m was obtained, and a piece of paraffin was levitated at 1200 T/sup 2//m. Using a CO/sub 2/ laser combined with the cryogenfree hybrid magnet, a containerless melting experiment in magnetic levitation was demonstrated easily for paraffin.
Keywords :
homocysteine , Cretan Mediterranean diet , Ischaemic heart disease , folate