• Title of article

    Night energy balance in a heated low-cost plastic greenhouse

  • Author/Authors

    A. Baille، نويسنده , , J.C. Lopez-Marcos، نويسنده , , S. Bonachela ، نويسنده , , M.M. Gonzalez-Real، نويسنده , , J.I. Montero، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    12
  • From page
    107
  • To page
    118
  • Abstract
    This paper analyses the night energy balance of an air-heated greenhouse in mild-winter climatic conditions (Almería, South-eastern Spain). The components of the energy balance of the air volume, soil and cover surfaces were determined in a low-cost plastic structure (parral-type), devoid of crop, under continuous and constant inflow of heat into the inside air at moderate (62 W m−2) and at high (134 W m−2) heating input. For typical winter weather conditions and heating practices in the Almería region, corresponding to the moderate heating input, the energy balance at the soil–air interface showed that the soil heat flux provided most of the energy to compensate for the radiative ground losses, and only a very small amount of sensible energy, of the same order of magnitude as the residual soil evaporation (<5 W m−2), was exchanged between the air and the soil surface. In the greenhouse air volume, energy losses mainly occurred through air-inner cover convective exchange (≈50 W m−2). At the cover, losses mostly occurred by radiative exchange, the convective component being relatively small (between ±10 W m−2). For the high heating input, the soil radiative losses were compensated by both the soil conduction flux (about 15 W m−2) and the soil-to-air convective heat transfer (about 20 W m−2). Radiative losses were also found to be the major component of the cover losses, whereas the convective component reached one-third of the total cover loss. For the two heating levels, leakage losses reached up to 35% of the heating input at high wind speed. The increase in leakage losses with wind speed led to a consequential decrease of the cover convective fluxes and to a negative relationship between the latter and the wind speed. Estimates of the convective heat transfer coefficients between the inside air and surfaces (soil and inner cover), and between the outside air and the outer cover, supply values within the range reported in the literature. The influence of the air mixing due to the air heating systems on the inside air-to-cover heat coefficient was demonstrated. In conclusion the measures to improve the energy efficiency would be: (i) to improve the air tightness of the greenhouse, (ii) to reduce radiative losses by means of thermal screens or IR-opaque plastic covering materials, and (iii) to increase the soil efficiency in storing solar energy and releasing it during the night.
  • Keywords
    Heating system , Energy balance , Radiative heat loss , Convective heat loss , Heat transfer coefficient
  • Journal title
    Agricultural and Forest Meteorology
  • Serial Year
    2006
  • Journal title
    Agricultural and Forest Meteorology
  • Record number

    959448