Title of article
LDV assisted bubble dynamic parameter measurements from two enhanced tubes boiling in saturated R-134a
Author/Authors
Hsieh، Shou-Shing نويسنده , , Tsai، Huang-Hsiu نويسنده , , Lai، Wen-Chuan نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
-4910
From page
4911
To page
0
Abstract
LDV measurements and heat transfer experiments for nucleate pool boiling from two horizontal enhanced tubes with porous copper on copper surfaces immersed in saturated R-134a were conducted. The influence of tube position (alignment) and tube pitch on bubble dynamics and boiling characteristics were studied. Photographs indicate that the average number of bubbles increases with heat fluxes, which is the same as those in previous studies of single tube. However, the bubble departure diameters of the upper tube show an opposite trend with an increase as compared to previous single-tube studies. LDV measurements show that the present tube arrangement has significant influence on local velocity in both magnitude and trend. The heat transfer mechanism and modeling for the upper tube were studied and developed.
Keywords
Rotation , Perturbation method , Numerical simulation , Convective heat transfer , Helical pipes
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Serial Year
2003
Journal title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Record number
96361
Link To Document