Title of article
Pattern identification and perceived stimulus quality as a function of stimulation waveform on a fingertip-scanned electrotactile display
Author/Authors
K.A.، Kaczmarek, نويسنده , , S.J.، Haase, نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
-8
From page
9
To page
0
Abstract
The effect of stimulation waveform on pattern perception was investigated on a 49-point fingertipscanned electrotactile (electrocutaneous) display. Waveform variables burst frequency (F), number of pulses per burst (NPB), and pulse repetition rate (PRR) were varied in a factorial design. Contrast reduction was used to limit performance of perceiving a 1-tactor gap defined within a 3 * 3 tactor outline square. All three variables accounted for significant variations in performance with higher levels of F and NPB and lower levels of PRR, leading to better performance. In addition, we collected qualitative data on each waveform, and the qualitative differences were related to performance (e.g., waveforms perceived as having a more localized sensation were correlated with better pattern identification performance than those waveforms perceived as more broad). We also investigated the effect of stimulation contrast on pattern perception.
Keywords
computational grids , Three-dimensional flow , Navier-Stokes equation