Title of article :
Determination of high energy β-emitters with a Ge spectrometer or Cherenkov radiation in an aerogel
Author/Authors :
D. BrajnikCorresponding author contact information، نويسنده , , a، نويسنده , , G. Medina، نويسنده , , A. Stanovnika، نويسنده , , b، نويسنده , , M. Starica، نويسنده ,
Issue Information :
هفته نامه با شماره پیاپی سال 1995
Pages :
6
From page :
225
To page :
230
Abstract :
Two types of coincidence measurements of β-radiation are described. In both cases a thin multiwire proportional chamber (MWPC) selects the useful events. In the first experiment a GeHP detector with a thin window is used as a β-spectrometer. Cherenkov radiation in silica aerogel with a low refractive index of 1.055 is used as an alternative method of discrimination of high energy β-emitters like 90Sr/Y in thin samples. A detection limit for 90Sr/Y of 0.1/0.5 Bq was obtained in few hours in samples containing no other high energy β-emitters. Elimination of contribution of β-γ-emitters is discussed for both experiments.
Keywords :
Beta spectrometry , Cherenkov radiation , 90Sr/Y
Journal title :
Science of the Total Environment
Serial Year :
1995
Journal title :
Science of the Total Environment
Record number :
979737
Link To Document :
بازگشت