Abstract
Quantification and characterisation of suspended particulate matter (SPM) from homes in the city of Oslo was carried out. In 29 households the dust concentrations were found to vary between 9 and 56 μg/m3 (median value 26 μg/m3). In 12 of the 29 households, a thorough analysis was carried out to determine the size and element distribution of the particles using transmission electron microscopy (TEM) and X-ray microanalysis (XRMA). The vast majority of the collected particles were less than 2.5 μm in diameter, i.e. they belonged to the fine fraction. In this fraction a considerable amount of soot and sulphur particles were found, usually less than 1 μm in diameter. The coarse fraction (particles > 2.5 μm in diameter) was found to consist mainly of organic material, silicates and larger soot aggregates. Both a thorough analysis of individual particles and a ‘bulk analysis’ (i.e. recording XRMA spectra from whole grid masks) were performed, and the two methods were found to show good agreement.
Keywords
Indoor air , Airborne dust , Suspended particulate matter , Transmission electron microscopy , X-Ray microanalysis