Title of article :
Evaluation of enzyme-linked immunosorbent assay for the determination of polycyclic aromatic hydrocarbons in house dust and residential soil
Author/Authors :
Jane C. Chuang، نويسنده , , Mary A Pollard، نويسنده , , Ying-Liang Chou، نويسنده , , Ronald G Menton، نويسنده , , Nancy K Wilson، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
11
From page :
189
To page :
199
Abstract :
Two commercially available enzyme-linked immunosorbent assays (ELISA) for total polycyclic aromatic hydrocarbon (PAH) and carcinogenic PAH (C-PAH) were evaluated. The testing procedures were refined for application to screening PAH and C-PAH in house dust and soil samples for human exposure studies. The overall method precision expressed as percent relative standard deviation (%RSD) of triplicate real world dust and soil samples was within ±29% (12–29%) for PAH ELISA and ±21% (5.9–21%) for C-PAH ELISA. Spike recoveries from real world dust/soil samples were 114±30% for phenanthrene from PAH ELISA and 120±8.2% for benzo[a]pyrene from C-PAH ELISA. The overall method accuracy for PAH and C-PAH assays cannot be assessed for multiple PAH components in dust/soil samples (which represent real-world samples), because of the assaysʹ cross reactivities with other PAH components. Over 100 dust/soil samples from 13 North Carolina homes and 22 Arizona homes were analyzed by PAH and C-PAH assays, as well as by the conventional gas chromatography/mass spectrometry (GC/MS) method. Statistical analysis showed that dust/soil PAH data from ELISA and GC/MS methods are significantly different. In general PAH ELISA responses were higher than PAH GC/MS responses. The regression analysis showed that the linear relationship between ELISA and GC/MS measurements is not strong in the combined data. The relationship became stronger for the data from the same type of dust/soil samples. The screening performance of ELISA was evaluated based on the frequency distribution of ELISA and GC/MS data. The results indicated that the ELISA PAH and C-PAH assays cannot be used as a quantitative analytical tool for determining PAH in real-world dust/soil samples. However, the ELISA is an effective screening tool for ranking PAH concentrations in similar types of real world dust/soil samples.
Keywords :
Enzyme-linked immunosorbent assay , ELISA , Polycyclic aromatic hydrocarbons , PAH , Dust , GC/MS , Soil
Journal title :
Science of the Total Environment
Serial Year :
1998
Journal title :
Science of the Total Environment
Record number :
981388
Link To Document :
بازگشت